Address
49 Pasteur, phường Nguyễn Thái Bình, Quận 1, TP. Hồ Chí Minh.
Recognition content
The list of testing criteria eligible for specialized construction activities of the LAS-Construction 666 laboratory at location 1 includes: Testing welded metal and 93 testing criteria at location 2 including: Construction land; Aggregate for concrete and mortar; Heavy concrete mix; Heavy concrete; Construction mortar; Cement; Cement, Clinker, Blast furnace slag; Alumina cement; Mineral additives for cement; Mineral additives for concrete and mortar; Chemical additives for concrete; Asphalt; Mineral powder for asphalt concrete; Asphalt concrete; Fired clay bricks; Self-inserting concrete tiles; Concrete bricks; Lightweight concrete bricks; Refractory brick; Terazo brick; Ceramic; Natural paving stone; Asbestos-cement roofing sheets; Plasterboard; Phosphorus gypsum used to produce cement; Activated fly ash additive used for concrete, mortar and cement; Fiber cement panels; Artificial wood planks; Wall plaster powder; Construction glass panels - Float glass, drawn glass; Patterned rolled glass; Colored glass absorbs heat; Reflective coated glass; Thermal tempered glass is safe in construction; Laminated glass and laminated safety glass used in construction; Mirror glass; Semi-tempered glass; Low radiation coated glass; Waterproofing sheets based on modified bitumen; Cement-polymer based waterproofing materials; Geotextile; Wood; Sanitary ceramic products; Steel bars reinforcing concrete; Sleepers; Track; Bolts; Steel pipe; Concrete reinforced steel - Threaded pipe joints; Plain bridge bearings and bridge bearings with reinforced plates; Pot pillow; Metallic material; Coating; Check the quality of concrete and cement mortar; Bentonite; Water for mixing concrete, mixing mortar, washing aggregates and curing concrete; Check the quality of the pavement structure layer; Check prestressed concrete pipe piles; Check centrifugal concrete electric poles; Check prestressed concrete sheet piles; Check reinforced concrete drainage pipes and reinforced concrete box culverts; Check precast thin-walled reinforced concrete ditches; Inspection of precast thin-walled reinforced concrete technical trenches; Inspection of prefabricated thin-walled reinforced concrete manholes – Part 1. Rainwater collection pits and odor prevention pits; Inspection of precast thin-walled reinforced concrete manholes – Part 2. Box-shaped manhole; Precast thin-walled fiber-reinforced concrete ditch; Prefabricated thin-walled reinforced concrete septic tank for toilets; Precast concrete and reinforced concrete structures; Precast concrete hollow wall panels; 3D panels used in construction; Check pile quality; Checking project quality; Plastic pipe systems for underground and above-ground water supply, drainage and sewer systems under pressure - Unplasticized polyvinyl chloride (PVC-U); Unplasticized Polyvinyl chloride pipes (PVC-U) for water supply systems placed underground and above ground under pressure; Polyethylene (PE) plastic pipes used for water supply; Polypropylene (PP) plastic pipes are used to carry hot and cold water; Unplasticized poly(vinyl chloride) profile (PVC-U) used to make windows and doors; Profile aluminum alloy products used to make windows and doors; Group of paint products, waterproofing materials and joint sealing materials; Emulsion wall paint; Epoxy paint; Alkyd paint; PVC water blocking tape; Silicon joint sealant for construction structures. Technical standards used for tests are fully listed, including Vietnamese and foreign standards (if any). When there is a new version of technical standards to replace the old standards, the corresponding new standards must be applied. This certificate is valid for 05 years from the date of issue and replaces Decision No. 394/QD-BXD dated September 7, 2011 of the Minister of Construction.